Laboratory

 

Accreditation of the Calibration Laboratory

Up-to-date and complete information on the scope of accreditation can be found here

Actual member of the POLLAB Club

The POLLAB Club Member is a prestigious membership of our Laboratory in the Polish Research Laboratories Club.

The aim of the Club is mutual cooperation and exchange of experience in the field of practical implementation and improvement of management systems, provisions of standards and legal regulations as well as the requirements of the accreditation bodies. More information about the Club can be found at: www.pollab.pl

 

Wzorcowanie

 

 

Calibration within the scope of the Laboratory's Accreditation with the Comparative Method of the following equipment


  1. Pyrometers, thermovision cameras, line scanners in the range from
    -18 °C do 1700 °C

  2. Industrial sensors of resistance thermometers (Pt100) in the range from
    -40 °C do 550 °C

  3. Thermocouple sensors from precious metals (S, R) in the range from
    od 0 °C do 1500 °C

  4. Thermocouple sensors from precious metals (B) in the range from
    od 400 °C do 1500 °C

  5. Thermocouple sensors from non-precious metals (E, J, K, N, T) in the range from
    od 0 °C do 1260 °C

  6. Electrical and electronic thermometers in the range from
    -20 °C do 1500 °C (in agreed cases - also at the customer's premises, in the range from 50 ° C to 650 ° C)

  7. Indicators, meters, including temperature controllers
    (in agreed cases - also at the customer's premises)

  8. Temperature simulators (calibrators)
    (voltage and current channels outside the scope of the accreditation)


Calibration outside the scope of laboratory accreditation


  1. Calibration of industrial sensors of resistance thermometers (Pt500, Pt1000, Cu50)

  2. Calibration of medical pyrometers (electronic thermometers for ear and forehead)

  3. Calibration of radiation pyrometers in the range from -30 ° C to -18 ° C

  4. Calibration of dryers, chambers and laboratory furnaces (also at the customer's premises)

Calibration in the scope of laboratory accreditation with the Fixed Point Method


  • Calibration of long platinum resistance thermometers: 25 Ω and 25.5 Ω (SPRT), in fixed point cells:
    • triple point of mercury, Hg (-38.8344 ° C)
    • triple point of water, H2O (0.01 ° C)
    • Gallium melting, Ga (29.7646 ° C)
    • Tin solidification, Sn (231,928 ° C)
    • Zinc solidification,, Zn (419.527 ° C)
    • Aluminum solidification, Al (660.323 ° C)
  • Calibration of S-type control thermocouples (PtRh10-Pt), R (PtRh13-Pt) and B (PtRh30-PtRh6) in fixed point cells:
    • Zinc solidification, Zn (419.527 ° C)
    • Aluminum solidification, Al (660.323 ° C)
    • Copper solidification, Cu (1084.62 ° C)
    • Gold melting, Au (1064.18 ° C) with the wire method
    • Palladium melting, Pd (1553.5 ° C) with the wire method
  • Calibration of long, high-stability platinum sensors of resistance thermometers 100 Ω (reference, semiconductor SSPRT), in fixed point cells:
    • triple point of mercury, Hg (-38.8344 ° C)
    • triple point of water, H2O (0.01 ° C)
    • gallium melting, Ga (29.7646 ° C)
    • Tin solidification, Sn (231.928 ° C)
    • Zinc solidification, Zn (419.527 ° C)
    • Aluminum solidification, Al (660.323 ° C)

 

Calibration services for measuring instruments fitted in the facility (at the customer's premises) are performed only in agreed cases.

Up-to-date and complete information about the scope of accreditation can be found in a document on the website of the Polish Center for Accreditation and in the following file.

 

 